This is a replacement parts & accessories → flow controls → flow controls - other. It is suitable for replacing HENRY Air Conditioners.

SALIN is a leading Australian appliance spare parts distributor for many types of applicances. We take pride in our ability to bring hard-to-find spare parts into the Australian market. We are proudly Australian-owned and operated. Our sales office is conveniently located in Sydney, NSW.

TECHNICAL SHEET
TitleFlow Controls - Other | Henry PRV 1/2"MNPT inlet x 5/8"MSAE outlet 40.0 BAR (580 psi) | PN: 5231BX-40
BrandHenry
Replacement ItemParts & Accessories → Flow Controls → Flow Controls - Other
Suitable ForAir Conditioners
MPN5231BX-40
SKU NumberKRB_0003365
Notes

Henry PRV 1/2"MNPT inlet x 5/8"MSAE outlet 40.0 BAR (580 psi)

The function of a Pressure Relief Valve is to protect against overpressure. For safety reasons, excessive over-pressure in any part of the
refrigeration system must be avoided
Applications
A typical application for a Henry Technologies pressure relief valve (PRV)
is to protect a liquid receiver from being over-pressurised. In the event
of a fire, any liquid refrigerant inside the receiver will evaporate resulting
in an increase in pressure. The PRV will safely control this increase in
pressure by venting the vapour from the receiver. Another application is
to protect equipment from compressor over-pressure.
Henry Technologies pressure relief valves are designed to discharge
vapour and should not be used to vent liquid refrigerant. The valves are
“back-pressure dependent” and are therefore required to discharge to
atmosphere.
The brass and stainless steel series valves are suitable for use with
HCFC and HFC refrigerant gases. The stainless steel series valves are
also suitable for ammonia.
Once a PRV has discharged, replacement is recommended, as the set
pressure can no longer be guaranteed. Refer to Installation Section for
further information.
In line with the Institute of Refrigeration Guidelines (UK), Henry Technologies recommend that a PRV should be replaced at least every 5 years. These intervals may have to be reduced if other regulations apply.
It is recommended to have a relief valve pressure setting at least 25%
higher than the maximum system operating pressure. The PRV set
pressure should not be higher than the design pressure (MWP) of the vessel

 

SALIN is not responsible for any possible damage caused by misselection and incorrect installation of the spare parts.

All electrical items must be fitted by a qualified electrician.

Errors and Omissions Excepted:

All information contained herein this website is assumed to be accurate, however, no responsibility is assumed by SALIN  for its use, nor for any infringements of patents or other rights of third parties which may result from its use.

Legal Disclaimer:

All trademarks, logos and principal representations remain the property of their respective owners. The use of brands, brand names and trademarks doesn't imply SALIN is representing those brands, companies, trademarks or names. SALIN holds no rights to products and/or services available or provided by the said companies, brands, brand names and trademarks.

AIRLINK
SKU KRB_0003365
Brand Henry
Shipping Weight 1.0000kg